TUFLOW Message 2051: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 6: | Line 6: | ||
|suggestions=Review boundary configuration, if a HX or SX boundary is desired ensure HX or SX object exists and CN object is correctly snapped. If no boundary is desired remove CN object. |
|suggestions=Review boundary configuration, if a HX or SX boundary is desired ensure HX or SX object exists and CN object is correctly snapped. If no boundary is desired remove CN object. |
||
|prelink=[[TUFLOW_Message_2050|Message 2050]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2052|Message 2052]] |
|||
}} |
}} |
||
Revision as of 11:40, 23 December 2022
TUFLOW Message
ERROR 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object.
Alternate Message
WARNING 2051 - Connection object unused or not snapped to a 2D HX or 2D SX object.
Description
Connection object unused or not snapped to a 2D HX or 2D SX object. All connections (CN objects) must be snapped to a 1D/2D interface object.
Suggestions
Review boundary configuration, if a HX or SX boundary is desired ensure HX or SX object exists and CN object is correctly snapped. If no boundary is desired remove CN object.
| Up |
|---|