TUFLOW Message 2063: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 6: | Line 6: | ||
|suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used. |
|suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used. |
||
|prelink=[[TUFLOW_Message_2062|Message 2062]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2064|Message 2064]] |
|||
}} |
}} |
||
Latest revision as of 11:54, 23 December 2022
TUFLOW Message
ERROR 2063 - Single CN connection to 1D Node must have a weighting factor (f) of 1.0.
Alternate Message
NA
Message Type
ERROR
Description
Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0). As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
Suggestions
If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.
| Up |
|---|