TUFLOW Message 2215: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 6: | Line 6: | ||
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. |
|suggestions=Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a '''very''' large pit object is modelled which requires connection to more 2D cell than the maximum a '''SX''' boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit. |
||
|prelink=[[TUFLOW_Message_2214|Message 2214]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2216|Message 2216]] |
|||
}} |
}} |
||
Revision as of 14:11, 7 February 2023
TUFLOW Message
WARNING 2215 - Exceeded limit of 2D cells connected to 1D pit object.
Alternate Message
NA
Message Type
WARNING
Description
A 1D pit object can be connected to a maximum of 10 2D cells.
Suggestions
Change number of cells pit is connected to using the Conn_No attribute in the 1d_nwk layer. If a very large pit object is modelled which requires connection to more 2D cell than the maximum a SX boundary can be manually specified in a 2d_bc layer, this gives the user control over the cells connected to the pit.
| Up |
|---|