TUFLOW Message 3007: Difference between revisions
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 3007 |
|tuflow_message=ERROR 3007 - Wet/dry depth threshold must be >= 0.0001. |
||
<br> |
|alt_msg=NA<br> |
||
|alt_msg=none |
|||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=The wet/dry depth threshold has been set to a value below the minimum allowed. |
|message_desc=The wet/dry depth threshold has been set to a value below the minimum allowed.<br> |
||
The default is 0.002m (2mm) or 0.007ft if using <font color="blue"><tt>Units </tt></font> <font color="red"><tt>== </tt></font> <tt>US Customary</tt>. The depth should be selected according |
|||
| ⚫ | |||
to the magnitude of flooding depths. For broad-scale models with large cell sizes, values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of |
|||
steep flow, a wet/dry depth of less than 1mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct |
|||
rainfall models. |
|||
| ⚫ | |||
The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according to the magnitude of flooding depths. For broad-scale models with large cell sizes values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of steep flow, a wet/dry depth of less than a mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct rainfall models. |
|||
Revision as of 15:21, 2 March 2023
TUFLOW Message
ERROR 3007 - Wet/dry depth threshold must be >= 0.0001.
Alternate Message
NA
Message Type
ERROR
Description
The wet/dry depth threshold has been set to a value below the minimum allowed.
The default is 0.002m (2mm) or 0.007ft if using Units == US Customary. The depth should be selected according
to the magnitude of flooding depths. For broad-scale models with large cell sizes, values of up to 0.05m (0.16ft) have typically been used, while for models using the direct rainfall approach, or that have a high proportion of
steep flow, a wet/dry depth of less than 1mm (eg. 0.0002m or 0.0007ft) may be required due to the substantial amount of shallow sheet flow. A reduced wet/dry depth of 0.0002m (0.0007ft) is particularly recommended for direct
rainfall models.
Suggestions
Ensure that the value specified with the "Cell Wet/Dry Depth" tcf command is a depth > 0.0001m.
| Up |
|---|