TUFLOW Message 1100: Difference between revisions
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg= WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b". |
|alt_msg= WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b". |
||
|type=[[WARNING]] |
|type=[[WARNING]] |
||
|message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. |
|message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel. <br> |
||
The following diagrams provide a simplified elevation view of the two cases that trigger this warning: <br> |
|||
'''''Structure "a" crest/invert is below bed of primary upstream channel'''''<br> |
|||
[[File:Invert below US channel.png]] <br><br> |
|||
'''''Structure "a" crest/invert is below bed of primary downstream channel'''''<br> |
|||
[[File:Invert below DS channel.png]] <br> |
|||
<br> |
|||
|suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. |
|suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. |
||
Revision as of 10:38, 23 October 2023
TUFLOW Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b".
Alternate Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b".
Message Type
WARNING
Description
The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel.
The following diagrams provide a simplified elevation view of the two cases that trigger this warning:
Structure "a" crest/invert is below bed of primary upstream channel
Structure "a" crest/invert is below bed of primary downstream channel
Suggestions
For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.
| Up |
|---|