TUFLOW Message 1118: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
 
Line 3: Line 3:
|alt_msg=ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.
|alt_msg=ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples see Section 4.5.1.2 (Pit Inlet Database) of the TUFLOW manual (2010 version).
|message_desc=For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>.
|suggestions=Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.
|suggestions=Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.



Latest revision as of 09:52, 23 September 2024

TUFLOW Message
ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.

Alternate Message
ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.

Message Type
ERROR

Description
For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the TUFLOW Manual.

Suggestions
Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.


Up
1xxx Messages