− | |tuflow_message= | + | |tuflow_message=ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point. |
− | |alt_msg= | + | |alt_msg=ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.<br> |
− | + | CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.<br> | |
− | + | CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point. | |
− | |type=[[ | + | |type=[[ERROR]]<br> |
+ | [[CHECK]] | ||
|message_desc=A cell side encountered overlapping flow constrictions. | |message_desc=A cell side encountered overlapping flow constrictions. | ||
− | |suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. < | + | |suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more information. |
Latest revision as of 11:29, 7 October 2024
TUFLOW Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
Alternate Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
Description
A cell side encountered overlapping flow constrictions.
Suggestions
From 2023 release, overlapping flow constriction triggers an error.
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. Refer to the TUFLOW Manual for more information.