{{TUFLOW_Message
|tuflow_message=ERROR 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries.
|alt_msg=CHECK 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries.<br>
|alt_msg=NA<br>
 
|type=[[ERROR]]<br>
[[CHECK]]
|message_desc=A 1D node within the model has been connected to both a 2D SX and a 2D HX boundary. A node should only be connected to one of the boundary types.
|suggestions=Reconfigure the model to ensure the 1D node is connected to either a SX boundary OR a HX boundary. The _messages GIS layer spatially displays which node is triggering this error.