Difference between revisions of "TUFLOW Message 6024"

From Tuflow
Jump to navigation Jump to search
 
Line 3: Line 3:
 
|alt_msg=NA<br>
 
|alt_msg=NA<br>
 
|type=[[ERROR]]<BR>
 
|type=[[ERROR]]<BR>
|message_desc=
+
|message_desc= This happens if the node invert elevation at a node is higher than the elevation of an inlet at the same node. This is an invalid configuration that can lead to large mass errors.
|suggestions=
+
|suggestions= Determine whether the node elevation is incorrect and needs to be lower or the inlet elevation needs to be higher by reviewing source data and DEM and make the correction.
  
 
|uplink=[[6xxx_TUFLOW_Messages|6xxx Messages]]
 
|uplink=[[6xxx_TUFLOW_Messages|6xxx Messages]]
 
}}
 
}}

Latest revision as of 04:17, 3 December 2024

TUFLOW Message
ERROR 6024 - Invalid SWMM configuration: node invert elevation is higher than the inlet elevation for inlet at node <a>.

Alternate Message
NA

Message Type
ERROR

Description
This happens if the node invert elevation at a node is higher than the elevation of an inlet at the same node. This is an invalid configuration that can lead to large mass errors.

Suggestions
Determine whether the node elevation is incorrect and needs to be lower or the inlet elevation needs to be higher by reviewing source data and DEM and make the correction.


Up
Go-up.png 6xxx Messages