TUFLOW Message 2126: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, |
|message_desc=When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, the .tcf command "<font color="blue"><tt>Bed Resistance Values</font><font color=red> == </tt></font>" must be set to "<tt>MANNING N</tt>". Refer to the TCF Appendix of the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details. |
||
|suggestions= |
|suggestions=In the .tcf, set "<font color="blue"><tt>Bed Resistance Values</font><font color=red> == </font>MANNING N</tt>". <br> |
||
If |
If bed resistance values are set using the .tgc command "<tt><font color=blue>Set CnM</font><font color=red> == </font></tt>", "<tt><font color=blue>Read GIS CnM</font><font color=red> == </font></tt>", or "<tt><font color=blue>Read Grid CnM</font><font color=red> == </font></tt>", ensure the "<tt><font color=blue>Read Materials File</font><font color=red> == </font></tt>" command is commented out/removed in the .tcf. |
||
|prelink=[[TUFLOW_Message_2125|Message 2125]] |
|||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
||
|nextlink=[[TUFLOW_Message_2127|Message 2127]] |
|||
}} |
}} |
||
Revision as of 11:25, 28 May 2025
TUFLOW Message
ERROR 2126 - Material resistance values can only be specified for Manning's n at present.
Alternate Message
NA
Message Type
ERROR
Description
When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, the .tcf command "Bed Resistance Values == " must be set to "MANNING N". Refer to the TCF Appendix of the TUFLOW Manual for more details.
Suggestions
In the .tcf, set "Bed Resistance Values == MANNING N".
If bed resistance values are set using the .tgc command "Set CnM == ", "Read GIS CnM == ", or "Read Grid CnM == ", ensure the "Read Materials File == " command is commented out/removed in the .tcf.