Difference between revisions of "TUFLOW Message 2126"

From Tuflow
Jump to navigation Jump to search
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, [https://docs.tuflow.com/classic-hpc/manual/2025.0/TCFCommands-1.html#tcfBedResistanceValues <font color="blue"><tt>Bed Resistance Values</tt></font>] must be set to "Manning N".
+
|message_desc=When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, the .tcf command "<font color="blue"><tt>Bed Resistance Values</font><font color=red> == </tt></font>" must be set to "<tt>MANNING N</tt>". Refer to the TCF Appendix of the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for more details.  
|suggestions=Set [https://docs.tuflow.com/classic-hpc/manual/2025.0/TCFCommands-1.html#tcfBedResistanceValues <font color="blue"><tt>Bed Resistance Values</tt></font>] to "Manning N". <br>
+
|suggestions=In the .tcf, set "<font color="blue"><tt>Bed Resistance Values</font><font color=red> == </font>MANNING N</tt>". <br>
If setting bed resistance values using [https://docs.tuflow.com/classic-hpc/manual/2025.0/TGCCommands-1.html#tgcSetCnM <font color="blue"><tt>Set / Read GIS / Read GRID CnM</tt></font>] command, make sure [https://docs.tuflow.com/classic-hpc/manual/2025.0/TCFCommands-1.html#tcfReadMaterialsFile <font color="blue"><tt>Read Materials File</tt></font>] command is commented out in tcf file.  
+
If bed resistance values are set using the .tgc command "<tt><font color=blue>Set CnM</font><font color=red> == </font></tt>", "<tt><font color=blue>Read GIS CnM</font><font color=red> == </font></tt>", or "<tt><font color=blue>Read Grid CnM</font><font color=red> == </font></tt>", ensure the "<tt><font color=blue>Read Materials File</font><font color=red> == </font></tt>" command is commented out/removed in the .tcf.
  
|prelink=[[TUFLOW_Message_2125|Message 2125]]
 
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
 
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
|nextlink=[[TUFLOW_Message_2127|Message 2127]]
 
 
}}
 
}}

Revision as of 11:25, 28 May 2025

TUFLOW Message
ERROR 2126 - Material resistance values can only be specified for Manning's n at present.

Alternate Message
NA

Message Type
ERROR

Description
When using 2d_mat materials layers and a material file to specify the bed resistance values for 2D domains, the .tcf command "Bed Resistance Values == " must be set to "MANNING N". Refer to the TCF Appendix of the TUFLOW Manual for more details.

Suggestions
In the .tcf, set "Bed Resistance Values == MANNING N".
If bed resistance values are set using the .tgc command "Set CnM == ", "Read GIS CnM == ", or "Read Grid CnM == ", ensure the "Read Materials File == " command is commented out/removed in the .tcf.


Up
Go-up.png 2xxx Messages