{{TUFLOW_Message
|tuflow_message=ERROR 1069 - No Manning's n value found for Material ",a,"<material id> in cross-section ",a,"<cross-section name> in ",a,<cross-section path>
|alt_msg=NA
|type=[[ERROR]]
|message_desc=The Material ID specified in the cross-section is not defined in the materials dataset (as defined by the "Read Materials File == " in the .tcf). When using the "M" flag on 1D cross-sections, TUFLOW is expecting an integer material ID. The roughness value is obtained from the material dataset.<br>
|message_desc=????
This is in contrast to the "N" flag, if this flag is used the Manning's value is defined on the cross-section.
|suggestions=????
|suggestions=Check that the material ID specified exists in the Materials dataset. If the outputted material ID in the error message is 0, check that a material ID and not a Manning's value has been specified on the cross-section.