Line 2: | Line 2: | ||
|tuflow_message=ERROR 1092 - No flow area provided for pit type ",a,". | |tuflow_message=ERROR 1092 - No flow area provided for pit type ",a,". | ||
|alt_msg=NA | |alt_msg=NA | ||
− | |type=[[ERROR]] [[WARNING]] | + | |type=[[ERROR]]<br> |
+ | [[WARNING]] | ||
|message_desc=Caused when a zero width or zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1092 or 1093 is issued and the model simulation will not stop. | |message_desc=Caused when a zero width or zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1092 or 1093 is issued and the model simulation will not stop. | ||
|suggestions=Check for a zero width or zero flow area within a Q pit. | |suggestions=Check for a zero width or zero flow area within a Q pit. |
Revision as of 16:50, 19 September 2014
TUFLOW Message
ERROR 1092 - No flow area provided for pit type ",a,".
Alternate Message
NA
Description
Caused when a zero width or zero flow area for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If 'Defaults == Pre-2012' is set, a WARNING 1092 or 1093 is issued and the model simulation will not stop.
Suggestions
Check for a zero width or zero flow area within a Q pit.