TUFLOW Message 1133: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1133 - Number of columns in M channel flow matrix not same as in first row. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???...' |
Steph.dufour (talk | contribs) No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=If the number of characters in a single line of an M channel stage-discharge or stage-area .csv file exceeded 1,000, TUFLOW ignores the remaining values and issues this error message. |
|||
|message_desc=???? |
|||
|suggestions=Simulate the model for Build 2012-05-AC or later where the limit of 1,000 characters has been increased to 10,000. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 1133|Discuss Message 1133]] |
|discussion_page=* [[Talk:TUFLOW Message 1133|Discuss Message 1133]] |
||
|link3='' |
|link3='' |
||
Revision as of 09:51, 23 September 2014
TUFLOW Message
ERROR 1133 - Number of columns in M channel flow matrix not same as in first row.
Alternate Message
NA
Message Type
ERROR
Description
If the number of characters in a single line of an M channel stage-discharge or stage-area .csv file exceeded 1,000, TUFLOW ignores the remaining values and issues this error message.
Suggestions
Simulate the model for Build 2012-05-AC or later where the limit of 1,000 characters has been increased to 10,000.
| Up |
|---|