Difference between revisions of "TUFLOW Message 1527"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=ERROR 1527 - Could not find Operating Control Definition for Channel <Control_ID>.
+
|tuflow_message=ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=
+
|message_desc= The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.
|suggestions=
+
|suggestions= Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and “Define Control ==”…“End Define” logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.
 
|discussion_page=* [[Talk:TUFLOW Message 1527|Discuss Message 1527]]
 
|discussion_page=* [[Talk:TUFLOW Message 1527|Discuss Message 1527]]
 
|link3=''
 
|link3=''

Revision as of 14:01, 2 February 2015

TUFLOW Message
ERROR 1527 - Could not find Operating Control Definition for Channel 'a'.

Alternate Message
NA

Message Type
ERROR

Description
The channel 'a' is a structure, pump or other device that is to be controlled by operating rules (denoted by adding the optional flag 'O' to the 1d_nwk type). The rules associated with channel 'a' cannot be found.

Suggestions
Ensure that a <control_id> has been entered for the Inlet_Type attribute within the 1d_nwk object for channel 'a'. Check that a Operating Controls .toc file has been created and “Define Control ==”…“End Define” logic blocks have been specified for <Control_id>. Note that more than one channel can reference the same operational control logic.


Up
Go-up.png 1xxx Messages