(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=The ground level of the 2D cell (ZC level) is below the 1D bed level. 2D cells selected by 1D/2D (HX) interface lines must at...') |
|||
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
− | |tuflow_message= | + | |tuflow_message=ERROR 2044 - 2D HX cell ZC level is below 1D bed level. |
+ | |alt_msg=WARNING 2044 - 2D HX cell ZC level is below 1D bed level. <br> WARNING 2044 - ZC level of ",a," at 2D HX cell is below interpolated node bed level of | ||
+ | |type=[[ERROR]] <br> [[WARNING]] | ||
|message_desc=The ground level of the 2D cell (ZC level) is below the 1D bed level. 2D cells selected by 1D/2D (HX) interface lines must at or above the bed level of the 1D channel. This error usually occurs when the 1D/2D interface line (HX line) passes through a depression that is lower than the bed levels of the 1D cross-sections. | |message_desc=The ground level of the 2D cell (ZC level) is below the 1D bed level. 2D cells selected by 1D/2D (HX) interface lines must at or above the bed level of the 1D channel. This error usually occurs when the 1D/2D interface line (HX line) passes through a depression that is lower than the bed levels of the 1D cross-sections. | ||
|suggestions=???? | |suggestions=???? | ||
Line 7: | Line 9: | ||
|link4='' | |link4='' | ||
|prelink=[[TUFLOW_Message_2043|Message 2043]] | |prelink=[[TUFLOW_Message_2043|Message 2043]] | ||
+ | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
|nextlink=[[TUFLOW_Message_2045|Message 2045]] | |nextlink=[[TUFLOW_Message_2045|Message 2045]] | ||
}} | }} |
Revision as of 11:41, 1 October 2010
TUFLOW Message
ERROR 2044 - 2D HX cell ZC level is below 1D bed level.
Alternate Message
WARNING 2044 - 2D HX cell ZC level is below 1D bed level.
WARNING 2044 - ZC level of ",a," at 2D HX cell is below interpolated node bed level of
Description
The ground level of the 2D cell (ZC level) is below the 1D bed level. 2D cells selected by 1D/2D (HX) interface lines must at or above the bed level of the 1D channel. This error usually occurs when the 1D/2D interface line (HX line) passes through a depression that is lower than the bed levels of the 1D cross-sections.
Suggestions
????
Up |
---|
2xxx Messages |