TUFLOW Message 2050: Difference between revisions
Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or e...' |
No edit summary |
||
| Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 2050 - Lowest ZC elevation at/along SX link is above 1D node bed. |
|||
|tuflow_message=???? |
|||
|alt_msg=WARNING 2050 - Lowest ZC elevation at/along SX link is above 1D node bed. |
|||
|type=[[ERROR]] <br> [[WARNING]] |
|||
|message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual." |
|message_desc="The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual." |
||
|suggestions=???? |
|suggestions=???? |
||
| Line 7: | Line 9: | ||
|link4='' |
|link4='' |
||
|prelink=[[TUFLOW_Message_2049|Message 2049]] |
|prelink=[[TUFLOW_Message_2049|Message 2049]] |
||
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] |
|||
|nextlink=[[TUFLOW_Message_2051|Message 2051]] |
|nextlink=[[TUFLOW_Message_2051|Message 2051]] |
||
}} |
}} |
||
Revision as of 11:43, 1 October 2010
TUFLOW Message
ERROR 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.
Alternate Message
WARNING 2050 - Lowest ZC elevation at/along SX link is above 1D node bed.
Description
"The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual."
Suggestions
????
| Up |
|---|