Difference between revisions of "TUFLOW Message 2235"
Line 5: | Line 5: | ||
|message_desc=As of the 2010-10 release TUFLOW automatically creates a binary dump of selected input files. This allows TUFLOW to vastly speed up the start-up process next time a simulation is carried out. If the original input data does not have a save date later than its corresponding XF file, the XF file is used in preference to the original data. For more details on XF files see Section 4.13.2 of the 2010 TUFLOW Manual.<br> | |message_desc=As of the 2010-10 release TUFLOW automatically creates a binary dump of selected input files. This allows TUFLOW to vastly speed up the start-up process next time a simulation is carried out. If the original input data does not have a save date later than its corresponding XF file, the XF file is used in preference to the original data. For more details on XF files see Section 4.13.2 of the 2010 TUFLOW Manual.<br> | ||
<br> | <br> | ||
− | This message is occuring as TUFLOW failed to read binary version of Zpt file (XF files). | + | This message is occuring as TUFLOW failed to read binary version of Zpt file (XF files). TUFLOW should fall back to reading the original data layer instead. |
− | |suggestions=XF file may have been corrupted, deleting this file will cause TUFLOW to recreate it, next time the simulation is started. The creation of XF files can be | + | |suggestions=XF file may have been corrupted, deleting this file will cause TUFLOW to recreate it, next time the simulation is started. The creation of XF files can be globally turned off using the .tcf command <font color="green"><tt>XF Files == OFF</tt></font>, this can alose be turned off for individual files such as <font color="green"><tt>Read GIS Z Shape XF OFF</tt></font>. |
|discussion_page=* [[Talk:TUFLOW Message 2235|Discuss Message 2235]] | |discussion_page=* [[Talk:TUFLOW Message 2235|Discuss Message 2235]] | ||
|link3='' | |link3='' |
Revision as of 20:23, 18 June 2015
TUFLOW Message
WARNING 2235 - Unknown error reading ZPT XF file. XF file not read.
Alternate Message
NA
Message Type
WARNING
Description
As of the 2010-10 release TUFLOW automatically creates a binary dump of selected input files. This allows TUFLOW to vastly speed up the start-up process next time a simulation is carried out. If the original input data does not have a save date later than its corresponding XF file, the XF file is used in preference to the original data. For more details on XF files see Section 4.13.2 of the 2010 TUFLOW Manual.
This message is occuring as TUFLOW failed to read binary version of Zpt file (XF files). TUFLOW should fall back to reading the original data layer instead.
Suggestions
XF file may have been corrupted, deleting this file will cause TUFLOW to recreate it, next time the simulation is started. The creation of XF files can be globally turned off using the .tcf command XF Files == OFF, this can alose be turned off for individual files such as Read GIS Z Shape XF OFF.