|tuflow_message=ERROR 2306 - ????
|tuflow_message=ERROR 2306 - WrF value must be greater than zero
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]

Revision as of 20:41, 18 June 2015

TUFLOW Message
ERROR 2306 - WrF value must be greater than zero

Alternate Message
NA

Message Type
ERROR

Description
Occurs when a WrF (Weir calibration factor for upstream controlled weir flow) of zero has been found.

Suggestions
Check for zero values that may have been inadvertently applied using one or a combination of the following commands: Read GIS WrF==, Set WrF==, Read RowCol WrF==.