Difference between revisions of "TUFLOW Message 2001"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=???? |message_desc=An object is located outside the 2D domain that it is assigned to. The "Check Inside Grid" command controls whether this messa...')
 
Line 10: Line 10:
 
|link3=''
 
|link3=''
 
|link4=''
 
|link4=''
 +
|prelink=[[TUFLOW_Message_0003|Message 0003]]
 +
|nextlink=[[TUFLOW_Message_2002|Message 2002]]
 
}}
 
}}
{{Navigate Links|[[TUFLOW_Message_0003|Message 0003]]|[[TUFLOW_Message_2002|Message 2002]]}}
 

Revision as of 17:08, 21 July 2010

TUFLOW Message
????

Alternate Message
{{{alt_msg}}}

Message Type
{{{type}}}

Description
An object is located outside the 2D domain that it is assigned to. The "Check Inside Grid" command controls whether this message is an ERROR, WARNING or not given.

Suggestions
Make sure the object is in the 2D model domain. The .tcf can be modified to turn this check off by adding:
Check Inside Grid == Warning
or
Check Inside Grid == Off


Up
Go-up.png {{{uplink}}}