TUFLOW Version Backward Compatibility: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 3:
{|class="wikitable"
|-
|colspan="3"| '''2013-12-XX Builds'''
|-
 
| rowspan=1|2013-12-AA
| New default settings – see <font color="blue"><u>Defaults == PRE 2013-12</u></font> for a list of the commands that have changed in their default setting.
| Set <font color="blue"><u>Defaults == PRE 2013-12</u></font> if similar results are required to the 2012-05 release.
Line 84:
|-
 
|-
|colspan="3"| '''2007-07-XX Builds'''
|-
 
| rowspan=12| 2007-07-AA
|-
| Uses a new set of defaults for a number of commands (see <font color="blue"><u>Defaults).
| The new defaults may produce slightly different results. For established models run using the 2006-06-XX builds, use Defaults == PRE 2007-07-AA to use the default settings used by the 2006-06-XX builds. Testing of a range of models has shown zero change in results if Defaults == PRE 2007-07-AA switch is set. Each of the new default settings and their affects are discussed in the rows below.
|-
| Change <font color="blue">Zero Material Values to One == OFF</font> (previously ON)
| Will not cause different results if a Set Mat == 1 is specified before other material settings in the .tgc file, or if every cell has been assigned a material value.
|-
| <font color="blue"><u>Inside Region == Method B</u></font> (previously Method A)
| Testing thus far has not shown any difference between the two methods (other than the substantial gains in processing time of polygons).
|-
| <font color="blue"><u>Line Cell Selection == Method D</u></font> (previously Method C)
| May change results slightly, but improved stability and a smoother water levels along HX lines result.
|-
| <font color="blue"><u>VG Z Adjustment == MAX ZC</u></font> (previously ZC)
| May change results slightly, but stability should be significantly enhanced in some situations.
|-
| <font color="blue"><u>Bed Resistance Cell Sides == INTERROGATE</u></font> (previously AVERAGE M)
| Will influence results, usually slightly, but more pronounced where there are sudden changes in Manning’s n values such as in the urban environment.
|-
| <font color="blue">Culvert Flow == Method D</font> (previously Method C)
<font color="blue">Culvert Critical H/D == OFF</font> (previously Culvert Critical H/D == 1.5)
| The most significant influences are the selection of upstream or downstream controlled regimes depending on the H/D ratio, and the bug fix relating to Regime E if <font color="blue">Structure Losses == ADJUST</font>. Offers improved stability, better convergence for Regime C and smoother transitioning between some regimes.
|-
| Changed the setting of the default width (if eN1 < 0.001) of automatic weirs over R and C channels (i.e. RW and CW) to be the diameter/width multiplied by the number of culverts (previously, the width was not multiplied by the number of culverts).
| For backward compatibility, original weir width can be set by manually setting the eN1 attribute to the Diameter_or_Width attribute value of the culvert.
|-
| Bug fix that when using a restart file TUFLOW occasionally set the 2D FC bridge deck additional loss value incorrectly.
| No backward compatible workaround provided.
|-
| Bug fix that incorrectly set the water levels on dried VG cells (only applies to simulations with source inflows, e.g. SA or RF, somewhere within in the model).
| May cause slight changes in results. Backward compatibility provided if <font color="blue">Defaults == PRE 2007-07-AA</font> is set (noting that setting this command reinstates the bug). This bug also causes the mass error calculations to falsely give a mass error that is not occurring.
|-
| Fixed bug that did not correctly apply the reduction in conveyance for a FC BD (bridge deck) of FD (floating deck) cell using the 2d_fc Mannings_n attribute.
| Backward compatibility applied if <font color="blue">Defaults == PRE 2007-07-AA</font> is set, however, note that this reinstates the bug and the resistance to flow at FC BD and FD cells may need to be reviewed. Indications are that only minor changes in results occur. The flow area under 2D FC BD and FD cells is correctly calculated.