|tuflow_message=ERROR 2314 - Soil ID must be greater than 0 or less than 32767. Soil ID = 0.
|alt_msg=[[TUFLOW_Message_2514 | ERROR 2314 - Could not find end of points data flag ""</Pnts>"" in XML file ('''Note - As of TUFLOW 2016 this error message is now Error 2514''').]]
|alt_msg=NA
|type=[[ERROR]]
|message_desc= A 2D cell has been assigned a soil ID (integer) of less than one (1) or greater than 32,767. Soil IDs must be within this range. The most common reason for this is using a Soil ID value that hasn't been specified, in this case the MapInfo default integer of zero (0) is applied.