ERROR 0002 - Could not configure simulation log path into dongle - reason unknown.

Alternate Message
NA

Message Type
ERROR

Description
Could not configure simulation log path into dongle - reason unknown. This message should only be displayed if the -slp TUFLOW.exe option for storing the Simulations Log Folder on a SoftLok dongle fails. Note, the -slp option is not available for WIBU Codemeter dongles.

Suggestions
Check the length of the path is less than 65 characters (ERROR 0003 should result if it isn't). Check the dongle is being recognised by TUFLOW by double clicking on a TUFLOW.exe. For more information see Table 5.2 and the Simulations Log Folder == command in the 2010 TUFLOW Manual.