TUFLOW Message 0030

From Tuflow
Revision as of 09:02, 10 August 2011 by Bill Syme (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 0030 - Cannot use "BC Event Source" and "BC Event Text" together.

Alternate Message
NA

Message Type
ERROR

Description
These two commands cannot be used together. Event text definitions can only be defined using one of these commands. BC Event Source == became available with the 2010-10 release and allows up to 10 different event texts to be specified for assigning different event names, and is much more powerful than BC Event Text == which only allows one.

Suggestions
Rework the commands so that only one of the above commands exists. Note, there is no limit to the number of times either of these commands is specified in a model, they just can't both exist in the same model.


Up
Go-up.png 0xxx Messages