TUFLOW Message 2169

From Tuflow
Revision as of 13:48, 7 February 2023 by Melissa.Moghanloo (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
WARNING 2169 - THICK option not available with MIN or GULLY approach - ignored.

Alternate Message
NA

Message Type
WARNING

Description
THICK option not available with MIN or GULLY approach - ignored. The gully line approach lowers a continous flowpath in the direction of the line. The THICK line modifies all zpts in selected cells (as selected by "cross-hairs" approach), however if diagonal cells are selected this may not lower a continuous flow path.

Suggestions
Use THICK or GULLY approach but not both.


Up
Go-up.png 2xxx Messages