TUFLOW Message 1118

From Tuflow
Revision as of 16:26, 9 February 2024 by Abigail.lillo (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.

Alternate Message
ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.

Message Type
ERROR

Description
For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples see Section 4.5.1.2 (Pit Inlet Database) of the TUFLOW manual (2010 version).

Suggestions
Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.


Up
Go-up.png 1xxx Messages