TUFLOW Message 2902
Revision as of 14:30, 7 October 2024 by Emilie Nielsen (talk | contribs)
TUFLOW Message
WARNING 2902 - ‘Restart File Ignore Field’ does not include geometry, overwriting geometry in .tgc with restart file
Alternate Message
NA
Message Type
WARNING
Description
The TCF command Restart File Ignore Field == does not include geometry. The geometry in the TGC is overwritten with the restart file.
Suggestions
By default (without the TCF command Restart File Ignore Field ==), the geometry information in the restart file is ignored and the TGC information is used instead. However, if the Restart File Ignore Field == command is included, but does not include geometry, then this warning message is issued.
Refer to the TUFLOW Manual for more information on this command and its parameters.