TUFLOW Message 3548

From Tuflow
Revision as of 14:59, 12 November 2024 by Emilie Nielsen (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
CHECK 3548 - Setting SGS Sample Distance Target to minimum grid zpt resolution of "<>".

Alternate Message
NA

Message Type
CHECK

Description
Setting SGS Sample Distance Target to minimum grid zpt resolution of "<>". The .tcf commands "SGS Sample Target Distance ==" and "SGS Sample Frequency ==" were not defined. Therefore, a scan of the .tgc is performed to find the minimum raster grid resolution used in the "Read Grid Zpt ==" commands, and this is used as the sampling target distance to compute the sampling frequency.

Suggestions
If needed, use the .tcf commands "SGS Sample Target Distance ==" and/or "SGS Sample Frequency ==" to manually set the SGS distance.
Please refer to the TUFLOW Manual for more information.


Up
Go-up.png 3xxx Messages