ERROR 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries.

Alternate Message
CHECK 1462 - 1D node "<node_id>" is connected to both 2D SX and 2D HX boundaries.

Message Type
ERROR
CHECK

Description
A 1D node within the model has been connected to both a 2D SX and a 2D HX boundary. A node should only be connected to one of the boundary types. This message will show as a CHECK if tcf command "Defaults == Pre 2024" or ecf command "OVERLAPPING SX HX BOUNDARY== CHECK" is used.

Suggestions
Reconfigure the model to ensure the 1D node is connected to either a SX boundary OR a HX boundary. The _messages GIS layer spatially displays which node is triggering this error.