TUFLOW Message 2140
Revision as of 15:31, 4 October 2011 by tuflow>Par
TUFLOW Message
ERROR 2140 - Reading following line in control file.
Alternate Message
NA
Message Type
ERROR
Description
An error occurred reading the following line in the control file.
Suggestions
Check the line is a valid TUFLOW command for the version of TUFLOW that you are running. Common mistake are:
- Omitting the double equals (Set IWL = 0.6 not Set IWL == 0.6)
- Using the Read GIS syntax for versions of TUFLOW prior to 2010 (use Read MI instead
- Putting a command in the wrong file, e.g. putting a geometry (.tgc) command in the boundary file (.tbc)
Up |
---|
2xxx Messages |