TUFLOW Message 0046

From Tuflow
Revision as of 12:56, 5 June 2015 by Par (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 0046 - 1D Output Interval not specified.

Alternate Message
WARNING 0046 - 1D Output Interval not specified. Defaulting to every timestep.
ERROR 0046 - Time Series Output Interval not specified.
WARNING 0046 - Time Series Output Interval not specified. Defaulting to every timestep.

Message Type
ERROR
WARNING

Description
The output interval has not been specified using the tcf commands Time Series Output Interval or Output Interval (s), when simulating the model with Build 2013-12-AA or later. TUFLOW will issue an ERROR when using the default settings for the 2013 and subsequent versions of TUFLOW or a WARNING if Defaults == PRE 2013 (or earlier).
Specifying an output interval became mandatory as the default values for these intervals was every computational timestep, by not specifying values this could cause excessive amounts of memory to be allocated, and disk space to be required.

Suggestions
Specify the output interval using commands Time Series Output Interval or Output Interval (s).


Up