TUFLOW Message 1123
TUFLOW Message
ERROR 1123 - More than one cross-section line of same priority for channel
Alternate Message
NA
Message Type
ERROR
Description
Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priotity than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123.
Suggestions
Remove superlative cross-section.