TUFLOW Message 3027

From Tuflow
Revision as of 17:11, 19 April 2018 by Teegan.Burke (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3027: Roughness height specified but nLim less than 0. <br> |alt_msg=None |type=ERROR |message_desc=The limiting Manning’s n va...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 3027: Roughness height specified but nLim less than 0.

Alternate Message
None

Message Type
ERROR

Description
The limiting Manning’s n value, required for specifying bed resistance with the theoretically derived log law for shallow flows, must be greater than or equal to 0.0.

Suggestions
A limiting Manning’s n value based on the n value that would normally be applied is also specified to transition to conventional n values at greater depths.


Up
Go-up.png 3xxx Messages