TUFLOW Message 2239

From Tuflow
Revision as of 20:25, 18 June 2015 by Par (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
WARNING 2239 - Mass balance tracking time-series records exceeded allocated limit of <number of time-series> - please contact support@tuflow.com.

Alternate Message
NA

Message Type
WARNING

Description
The array limit of mass balance records retained throughout the simulation is exceeded. This can occur if the ISIS timestep is not equal to half the TUFLOW timestep, or if using the adaptive time stepping option. Prior to Build 2012-05-AC, TUFLOW would stop with a “Should not be here” message.

Suggestions
None. A permanent fix to this issue is planned for a future release. Note that the mass balance summary presented at the end of the simulation may not be complete.


Up
Go-up.png 2xxx Messages