TUFLOW Message 1214
Revision as of 15:45, 6 November 2018 by Pavlina Monhartova (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes. |alt_msg=NA |type=ERROR |message_desc=From 2017 onwards t...")
TUFLOW Message
ERROR 1214 - Invalid Conn_2D attribute at node - "SXL" only valid for pit nodes.
Alternate Message
NA
Message Type
ERROR
Description
From 2017 onwards the SXL option is no longer supported for Nodes (Type = Node or blank). SXL is only available for Pit objects (Type = C, Q, R, W).
Suggestions
If the node object is supposed to be a pit, specify type as C, Q, R or W. If the node object is a pipe outlet, change the SXL to SX and leave the US_Invert attribute blank.
Up |
---|