TUFLOW Message 3506

From Tuflow
Revision as of 14:15, 11 March 2020 by ShuangGao (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
CHECK 3506: Limiting SGS Grid sample frequency to upper limit of 'a'., sample distance of 'b'.

Alternate Message
N/A

Message Type
CHECK

Description
Too high an SGS sample frequency can result into long pre-processing time, and users may not benefit from applying a super fine sample distance against the model cell size. In general we found a sample frequency smaller than 31 is sufficient for most of natural water ways or artificial structures, and the default frequency limit is set as 31.

Suggestions
The default limit can be changed by using a second argument in the SGS Grid/TIN Sample Distance command, e.g. SGS Grid Sample Distance == 1 I 50 sets the sampling distance to 1 m and the frequency limit to 51


Up
Go-up.png 3xxx Messages