TUFLOW Message 2347

From Tuflow
Jump to navigation Jump to search

TUFLOW Message
ERROR 2347 - Insufficient header information in ASCII grid file [Location]. Check format of file.

Alternate Message
NA

Message Type
ERROR

Description
When processing a "Read Grid Location == ", the .asc format file is missing key data. The top lines of the .asc file contain information about the location and size of the .asc grid. For example:

ncols         100
nrows         100
xllcorner     1000
yllcorner     3000
cellsize      1
NODATA_value  -9999

If data is missing from this, Error 2347 may occur.

Suggestions
Check .asc file is valid and contains all header information.
Alternatively, use a different method for defining the model location, such as .tgc commands "Origin", "Orientation Angle", "Grid Size" or "Read GIS Location"


Up
Go-up.png 2xxx Messages