TUFLOW Message 2467

From Tuflow
Revision as of 14:10, 1 March 2023 by ElizaCollison (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.

Alternate Message
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.

Message Type
CHECK
ERROR

Description
A cell side encountered overlapping flow constrictions.

Suggestions
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. From 2023 release, overlapping flow constriction triggers an error.
Please contact support@tuflow.com.


Up
Go-up.png 2xxx Messages