Message Type
{{{type}}}

Description
"The lowest 2D cell centre elevation (ZC level) at/along the SX 1D/2D interface is above the bed of the connected 1D node or element. The lowest ZC level at or along the 1D/2D interface plus the 2D cell's wet/dry depth must be below the bed of the connected 1D element for SX type 1D/2D connections. SX connections are usually used for embedding small 1D elements such as pipes, culverts and manholes/pits. Treatment of this message as an ERROR or a WARNING is controlled by the ""SX ZC Check"" command. The ZC level of the 2D cell can be automatically lowered using ""Z"" in the Flag attribute for the object - see table of 2d_bc attributes in the manual."