ERROR 2314 - Soil ID must be greater than 0 or less than 32767. Soil ID = 0.

Alternate Message
NA

Message Type
ERROR

Description
A 2D cell has been assigned a soil ID (integer) of less than one (1) or greater than 32,767. Soil IDs must be within this range. The most common reason for this is using a Soil ID value that hasn't been specified, in this case the MapInfo default integer of zero (0) is applied.

Suggestions
Carry out a check to ensure a Soil ID greater than 0 has been assigned to all objects within any 2d_soil layers. Alternatively, use the Set Soil command prior to any Read GIS Soil or Read GRID Soil commands in the tgc file to ensure all cells in the 2D domain have been assigned a soil type.