TUFLOW Message 2625

From Tuflow
Revision as of 12:02, 25 March 2026 by Par (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 2625 - No polygons read for "RF Interpolation Method == Poly" |alt_msg=ERROR 2625 - No triangles read for "RF Interpolation Method == TIN" |type=ERROR |message_desc=These ERROR messages are issued when insufficient data is specified in the TUFLOW rainfall control file (.trfc). If using <font color="blue"><tt>RF Interpolation Method</tt></font> <font color="red"><tt>== </tt></font><font color="black"><tt>Poly</tt></font>" then v...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 2625 - No polygons read for "RF Interpolation Method == Poly"

Alternate Message
ERROR 2625 - No triangles read for "RF Interpolation Method == TIN"

Message Type
ERROR

Description
These ERROR messages are issued when insufficient data is specified in the TUFLOW rainfall control file (.trfc). If using RF Interpolation Method == Poly" then valid rainfall polygons must be read in with the command "Read GIS RF Polygons == <gis layer>".
Likewise, if using RF Interpolation Method == TIN" then valid triangles must be read with the command "Read GIS RF Triangles == <gis layer>".

Suggestions
Review the inputs and ensure that valid polygons or triangles are specified for the RF Interpolation Method.


Up
2xxx Messages