Revision as of 15:36, 30 March 2026 by ShuangGao (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=CHECK 2251 - HPC Infiltration Drying Depth not specified, set to Cell Wet/Dry Depth - 0.0001. |alt_msg=ERROR 2251 - HPC Infiltration Drying Depth must be smaller than Cell Wet/Dry Depth. <dry_depth>, <wet_depth> |type=CHECK ERROR |message_desc= When <font color="blue"><tt>HPC Infiltration Drying Approach </tt></font> <font color="red"><tt>== </tt></font> <font color="black"><tt>Method C</tt></font> (default) the drying depth to s...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

TUFLOW Message
CHECK 2251 - HPC Infiltration Drying Depth not specified, set to Cell Wet/Dry Depth - 0.0001.

Alternate Message
ERROR 2251 - HPC Infiltration Drying Depth must be smaller than Cell Wet/Dry Depth. <dry_depth>, <wet_depth>

Message Type
CHECK ERROR

Description
When HPC Infiltration Drying Approach == Method C (default) the drying depth to switch off infiltration calculation is set to Cell Wet/Dry Depth - 0.0001 by default.

Suggestions
The drying depth can be manually specified using the HPC Infiltration Drying Depth command.