TUFLOW Message 1104
TUFLOW Message 
ERROR 1104 - Diameter of C culvert is less than or equal to zero.
Alternate Message 
NA
Message Type 
ERROR
Description 
Diameter for circular culvert (C type channel) is less than or equal to zero.
Suggestions 
Ensure that the Width_or_Dia (14th filed) GIS attribute is greater than 0.  This diameter is in metres, not mm!