TUFLOW Message 2011

From Tuflow
Revision as of 10:53, 12 April 2011 by Bill Syme (talk | contribs)
Jump to navigation Jump to search

TUFLOW Message
ERROR 2011 - Using Mat command when no materials file has been specified.

Alternate Message
NA

Message Type
ERROR

Description
A .tgc materials command such as Set Mat == or Read GIS Mat == has been specified, but Read Materials File == in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used.
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.

Suggestions
{{{suggestions}}}


Up
Go-up.png 2xxx Messages