TUFLOW Message 0935
TUFLOW Message
CHECK 0935 - Licence lost. Count = ",a,". Pausing for ",a," seconds.
Alternate Message
NA
Message Type
CHECK
Description
Access to the licence has been lost.
As a background to the licencing, TUFLOW checks for a licence on model initialisation, and then periodically checks at a certain time interval, as well as at the end of the simulation. The CodeMeter licencing system used by TUFLOW will release any licences that are not in use after a period of time. This prevents the licence from being tied up forever by a force closed simulation (either closed through task manager or by clicking the red x at the top of the window).
This message indicates either TUFLOW could not find any licence during a periodic check, or the licence has been already released between two periodic checks.
Suggestions
Fixes of connectivity issues:
- TUFLOW may lose licences during a network failure or a licence server shutdown. Please make sure a modelling machine has a stable network access to the licence server.
- Some USB ports can lose power during a sleep mode and this can disconnect the licence dongle. Try plugging the licence dongle into a different USB port (preferably one of the USB ports on the back of the computer) as these should be much less likely to lose power / connectivity.
- Update your CodeMeter RunTime Kit, download available here: http://www.codemeter.de/us/service/downloads.html.
Infrequent licence checks:
Prior to built 2018-03-AA the licence could get lost for HPC/GPU runs when the map output was very infrequent. The infrequent output could cause TUFLOW to drop the licence and attempt to re-take the licence after a long period. A bug fix has been introduced for this in the 2018-03-AA build and later, but rarely, the licence can still get lost if the map output is infrequent, plus the model doesn't have any 1D or hidden 1D structures (e.g. a QT boundary). As a workaround:
- Include more frequent map output, possibly within an small dummy output zone to avoid large outputs.
- Include a dummy 1D channel to invoke the more frequent licence checks.
Please contact support@tuflow.com if the issue persist.