TUFLOW Message 3546

From Tuflow
Revision as of 09:14, 14 October 2022 by Pavlina Monhartova (talk | contribs) (Created page with "{{TUFLOW_Message |tuflow_message=ERROR 3546 - |type=ERROR WARNING |alt_msg=WARNING 3546 - |message_desc= If SGS Materials are on in combination with depth varying Ma...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 3546 -

Alternate Message
WARNING 3546 -

Message Type
ERROR WARNING

Description
If SGS Materials are on in combination with depth varying Manning’s n value error is issued and the simulation stops. If SGS Materials is enabled without depth varying Manning’s n values warning is issued.

Suggestions
Turn off SGS materials if depth varying Manning’s n is used. Check the use of SGS materials is intentional when depth varying Manning’s n is not used.


Up
Go-up.png 3xxx Messages