TUFLOW Message 2085

From Tuflow
Revision as of 12:00, 23 December 2022 by Melissa.Moghanloo (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 2085 - Read MID Mat or Read MID CnM cannot be used with Bed Resistance Cell Sides == INTERROGATE

Alternate Message
ERROR 2085 - Read MID Grid command cannot be used with Bed Resistance Cell Sides == INTERROGATE

Message Type
ERROR

Description
Read MID Mat, Read MID CnM or Read MID Grid .tgc commands cannot be used with Bed Resistance Cell Sides == INTERROGATE .tcf command. Specify Bed Resistance Cell Sides == AVERAGE n or Bed Resistance Cell Sides == AVERAGE M or Bed Resistance Cell Sides == MAXIMUM n in the .tcf file.

Bed Resistance Cell Sides == INTERROGATE is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the Read MID commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n. The two approaches are therefore incompatible.

Suggestions
Specify an interpolation method for cell sides (Bed Resistance Cell Sides == ) if using Read MID commands to define roughness. Or use GIS inputs (Read GIS MAT or FRIC == ) with Bed Resistance Cell Sides == INTERROGATE.


Up
Go-up.png 2xxx Messages