M02 Arc Error 2050 Archive
Revision as of 14:19, 6 January 2023 by ElizaCollison (talk | contribs) (Created page with "<ol> =Introduction= In this page we will use the messages layer generated by TUFLOW to locate the cause of an error. =Method= <ol><li>To locate the error load the '''M02_5m_00...")
- To locate the error load the M02_5m_001_messages_P.shp file from the TUFLOW\runs\log\ folder.
- To zoom to the location, right click on the layer in the "Layer Control" and select "Zoom To Layer". The error should be shown as per the image below. You may wish to change the style of the layer to make the point more obvious.
- The messages can also be labelled with the message text, using the layer properties dialogue.
- The message text indicates that the 1D bed has the elevation 32.75, whilst the 2D elevation is 42.75. Review of the DEM shows that the 2D elevations in the area are well above 40 metres and indicates that the 1D elevation has been incorrectly provided as 32.75 as opposed to 42.75.
Introduction
In this page we will use the messages layer generated by TUFLOW to locate the cause of an error.
Method
Conclusion
We have located the source of the error message, please return to the module 2 page, where we will address the issue.