CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
Alternate Message
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
Description
A cell side encountered overlapping flow constrictions.
Suggestions
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. From 2022 release, overlapping flow constriction triggers an error.