TUFLOW Message
ERROR 2373 - Invalid infiltration parameters entry for Material ",a,".

Alternate Message
ERROR 2373 - Invalid infiltration parameters entry for Material ",a,". Infiltration Parameters = "b".

Message Type
ERROR

Description
The infiltration value for the specified material cannot be read. The value must be numeric and greater than 0.

Suggestions
Review the materials file (.tmf or csv) and check the infiltration and loss values. If NO losses are to be applied, instead of 0, remove all entries (i.e.; a blank space).
If the infiltration parameter entry is a variable, check the variable has been defined using the "Set Variable" command.