TUFLOW Message 1101

From Tuflow
Revision as of 08:51, 23 September 2024 by Emilie Nielsen (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

TUFLOW Message
ERROR 1101 - Less than the mandatory 20 1d_nwk attributes found

Alternate Message
ERROR 1101 - Less than the mandatory 10 1d_pit attributes found.

Message Type
ERROR

Description
1D network layers (1d_nwk) should have the GIS attributes as described in the TUFLOW Manual.

Suggestions
Check the GIS attributes match those described in the TUFLOW manual or a 1d_nwk_empty layer created with the latest TUFLOW release. If it seems to be correct, recreate the layer from scratch using a 1d_nwk empty layer created with the latest TUFLOW release.
Check that the 1d_nwk layer being read in via the Read GIS Network == command is a network and not a boundary condition (1d_bc) or cross-section (1d_tab / 1d_xs) layer.


Up
Go-up.png 1xxx Messages